The motor test was refused: the outputs are blocked
What ArduPilot says:
- …: Motor Emergency Stopped
- …: Safety switch
The words before the colon say what was asked: “Motor Test” (the ground station's motor test) or “Turtle Mode”. It was refused because the motors cannot be driven. “Safety switch”: the hardware safety switch is still in its safe state, which keeps every output off. “Motor Emergency Stopped”: an emergency stop set from a switch on the transmitter is on.
What to do, most likely first
“Safety switch”: the safety button has not been pressed.
FixProps off. Hold the safety button until its light is steady, run the test, and press it again afterwards.
“Safety switch” on a board that has no safety button.
CheckNo button is wired (most small boards have none) and
BRD_SAFETY_DEFLTis 1.FixSet
BRD_SAFETY_DEFLTto 0 and reboot: with no button fitted there is nothing to press.“Motor Emergency Stopped”: a switch with
RCn_OPTION31 (Motor Emergency Stop) is high, or one with 165 (Arm/Emergency Motor Stop) is low.CheckThe start-up messages and each move of the switch show its state, like “RC8: MotorEStop HIGH”.
FixMove the switch to its run position, then repeat the test with the props off.
The motor test spins a motor with no stabilisation at all: take the props off first, every time.
Parameters to look at
| Parameter | What it is |
|---|---|
BRD_SAFETY_DEFLT | Sets default state of the safety switch |
RC7_OPTION | RC input option |
RC8_OPTION | RC input option |
Where to do it:Setup & Tuning Guide
The code that sends it
…: Motor Emergency Stopped
ArduCopter/motor_test.cpp Copter::mavlink_motor_control_check() · Open in ArduPilot Copter-4.7.1
…: Safety switch