The IMU heater has not reached its temperature yet

Stops itArming, disarming and the safety switch

What ArduPilot says:

Some flight controllers (the Cube family, for example) heat their motion sensors to a fixed temperature, because the sensors drift as they warm up. The message gives the temperature now and the lowest allowed for arming: BRD_HEAT_TARG minus BRD_HEAT_LOWMGN, in °C. Arming now would mean flying on sensors that are still changing.

What to do, most likely first

  1. It was powered on a moment ago and is still warming up.

    FixWait: a minute or two indoors, several minutes in the cold. The first number in the message climbs as it warms.

  2. It is so cold or windy that the heater never reaches the target.

    CheckThe temperature in the message stops rising below the limit.

    FixShield the flight controller from the airflow, or keep it warm until just before the flight.

  3. BRD_HEAT_TARG was raised, or BRD_HEAT_LOWMGN made very small.

    FixBring both back to the board's defaults.

Parameters to look at

ParameterWhat it is
BRD_HEAT_TARGBoard heater temperature target
BRD_HEAT_LOWMGNBoard heater temp lower margin
The code that sends it

PreArm: heater temp low (N.N < N)

libraries/AP_Arming/AP_Arming.cpp AP_Arming::heater_min_temperature_checks() · Open in ArduPilot Copter-4.7.1

Written here for Copter 4.6. In the tool you choose your vehicle and version, see your own parameter values beside the ones named here, and drop a flight log to have every message in it explained.